To ensure proper airflow and filter removal it is recom mended installation of the wall sleeve be a minimum of 36 from the ceiling.
Ptac wall sleeve installation.
It is the insta oohu vuhvsrqvlelolw to ensure there is adequate drainage for the ptac.
The kit installation instructions are included with the accessory kits.
Sleeve must be tight against the bottom shim and fully bedded into sealant.
If you ve got more than a few inches showing then you need to install a sub base.
Wall sleeve installation 920 087 04 8 05 wall sleeve installation instructions pdxws note.
How much wall sleeve should show on the inside the wall sleeve houses the ptac chassis.
Figure 4 minimum interior and exterior note.
Wall is shown in table 1.
The sub base sits under the unit on the room side supporting the weight and keeping the unit level.
Place the unit into the sleeve and screw it in place.
Keys to proper installation.
Unit has a slight rearward slope within wall sleeve for proper drainage use tapered foam blocks.
If the sleeve projects more than 8 into the room a sub base or other means of support must be used.
The wall sleeve be installed a minimum of 36 from the ceiling.
16 6 410 m wall receptacle within 58 from bottom right side corner on 208.
Apply sealant to completely fill this pocket.
Pay attention to how much of the sleeve shows on the inside of the room.
Installation of a thru the wall.
Summary the above is the basic steps to install a through the wall air conditioner sometimes call a window wall slide out air conditioner.
Standard steel wall cases are 42 w 16 h 13 3 4 d.
Inches mm inches mm inches mm wall sleeve only 3 75 0 0 0 0 subbase kit 3 75 3 1 4 85 2 3 4 70.
All wall and window wall installations must provide for proper drainage.
In applications where the drain holes on the ptac wall sleeve are not exposed beyond the wall an internal drain system is recommended.
Wall case should be sealed caulked to the inside wall on all four 4 sides.
This is an animation i created to show how correct installation of a ptac unit can keep water intrusion from occurring.
Install a backer rod if necessary to maintain a consistent gap between the louver frame flange and ptac sleeve across the top and down both sides.
Snapease wall sleeve features and.
Every scenario will be different with wall type and power always changing.
If the distance between wall sleeve and wall will be at or near the minimum clearance distance mount these kits on the sleeve before installing the sleeve in the wall.
Install the sleeve and secure with mounting fasteners.
Wall case must be sealed caulked to outside wall on all four 4 sides.
Power it on and test it.
Insure that the unit is only installed in a wall structurally adequate to support the unit including the sleeve chassis and accessories.
Air conditioner unit is centered in wall sleeve and sealed with foam pads to prevent air leakage.
16 24 28 and 31 deep cases are available for thicker walls.